it time to replace your Electron Multiplier?
See
our new expanded selection with replacement parts for many new instruments! |
|
Click here to see
how a multiplier works.
See our selection
FlowChart. |
|
Click on any part number and it will be added to your order.
|
|
Multipliers |
|
| Description |
CPI P/N |
| Multiplier
Assembly for HP 4500 |
4200-010007 |
| Multiplier Assembly, ELAN 6000 |
4200-010011 |
| Multiplier, for VG PQ3 (Dual Mode) |
4200-010017 |
| Multiplier, for HP 5971/72, (w/lead
connection) |
4200-010025 |
| Multiplier-5988/88A/85/87(3
lead)30/80/81/82/83/84 |
4200-010065 |
| Multiplier and Mount for HP 5973, ETP Type |
4200-010180 |
| Multiplier, HP 59xx instr group, HP (small
horn) |
4200-010200 |
| Multiplier, HP59xx instr group, K |
4200-010201 |
| Multiplier, HP 5970-70A-70B |
4200-010202 |
| Multiplier, HP5989, High Energy D |
4200-010203 |
| Multiplier & Mount, PE Ion Trap & Saturn
I-III |
4200-010204 |
| Multiplier, Finnigan ITD, ITS40, Mag |
4200-010205 |
| Multiplier, Finnigan ITD, ITS-40, TSQ 70, (horn
only) |
4200-010206 |
| Multiplier, Finnigan Ppinici IN50 |
4200-010207 |
| Multiplier, Varian Saturn 2000 |
4200-010211 |
| Multiplier, VG Elemental, Plasma Quad I, II
& III |
4200-010213 |
| Multiplier HP 5971/72, HP (small horn) |
4200-010221 |
| Extrel Benchmark LCMS, Questar, each |
4200-010236 |
| Electron Multiplier, HP 7500 ICP-MS |
4200-010240 |
| Multiplier, Finnigan Element 1 |
4200-010242 |
| Multiplier & Mount, (large horn), for 5970 |
4200-07 |
|
|
|
CPI electron multipliers for HP GC/MS are designed to give
you several performance benefits over the standard element...
Vented Anode
CPI multipliers have vent holes to the anode of the detector. These vent holes allow for residual gases in the detector channel and anode to be removed during pumping. By removing these gases the performance and life of the detector is improved.
Grid
When input ions enter the horn of a detector secondary electrons are created. These electrons should travel down the channel of the detector, but occasionally the secondary electrons travel out of the horn. CPI multipliers have a grid on the front of the horn causing all secondary electrons to travel down the detector channel. This increases the signal-to-noise ratio and overall performance of the
detector.
Lower Operating Voltage
CPI multipliers operate at a lower voltage than the standard Hewlett Packard element. The tuning voltage is typically 1100V 1300V. By starting detector operation at a lower voltage overall lifetime is increased.
Increased Signal-to-Noise Ratio In a Hewlett Packard instrument the signal-to-noise of the instrument is increased approximately 25%. This is due to the mechanical design changes incorporated into the product, such as the vented anode and grid.
Robust Design CPI multipliers have a robust stainless steel frame to protect the glass detector from damage. |
|
|