Click on any part number and it will be added to your order.
|
| Teflon®
Parallel Path Nebulizer |
This
Teflon Parallel Path Nebulizer has the convenience of concentric
glass nebulizers with the advantage of a unique, unrestricted
sample path. The sample path has a constant diameter from the
pump to the gas orifice, so there is no capillary plugging. This
style of nebulizer is now OEM Equipment on TJA® TraceScan®
analyzers, and also fits most configurations of PE®, JY®, ARL®
and Fisons® ICP’s. Call for additional information on this
product. |
|
|
|
|
|
| Description |
CPI P/N |
OEM P/N |
| Parallel
Path Teflon Nebulizer, 25 to 45 psi |
4060-69 |
N/A |
| Long
Nose, High Solids Teflon Nebulizer and Fittings |
4060-694 |
TJA® / 136388-00 |
| Chamber
Adapter, for open end chambers, 35mm |
4060-691 |
N/A |
| 1/8”
to 1/4” Adapter, with ferrules |
4060-695 |
N/A |
| 1/4”
to 1/4” Adapter, with ferrules |
4060-696 |
N/A |
| Tubing
Assembly, Complete |
4060-698 |
N/A |
| Capillary
Tubing, 10 feet |
4060-697 |
N/A |
| Filter
Material, 1 gram |
4060-699 |
N/A |
| Viton
O-Ring, 10/pk for Teflon Nebulizer |
4060-6991 |
N/A |
|
|
|
|
|
| V-Groove
and Babbington Nebulizers |
| Description |
CPI P/N |
OEM P/N |
| Babbington
V-Groove Nebulizer, Peek, 1/2”OD |
4060-010012 |
N/A |
| MDSN
V-Groove, Glass |
4060-77 |
N/A |
| V-Groove
Nebulizer, Ceramic, 40psi, 0.8L/min |
4060-010391 |
N/A |
|
|
|
|
|
| Glass
Concentric Nebulizers |
CPI
Glass Concentric Nebulizers have been manufactured for
durability and performance.
Use of precision ground tubing for the sample path of
these nebulizers helps promote reproducibility of both sample
and gas flow. The
sample path inner diameter is designed to be narrow enough to
provide a fine, consistent aerosol but not so small that the
nebulizer is susceptible to clogging.
Each nebulizer tip is finished to precise specifications
to ensure a uniform aerosol pattern.
All dimensional and performance specifications are
checked as part of quality control.
These nebulizers are economically priced and guaranteed
for performance in your ICP. |
|
| Suggested
Instrument Application |
CPI P/N |
Argon
Press (PSI) |
Argon
Flow (Liters/min) |
Sample
Flow (mL/min) |
| All TJA® (or
4060-010162 w/Sample Tube) |
4060-602 |
30 |
0.7 |
2 |
| Varian Liberty®
Radial, Vista®, Ultramass® |
4060-60 |
30 |
0.7 |
3 |
| Jobin Yvon® |
4060-57 |
50 |
1 |
1 |
| ARL® 3500
Series, Varian® Axial, |
4060-58 |
30 |
1 |
3 |
| Perkin-Elmer®,
Elan® 5000/6000 |
|
| ARL Maxim® |
4060-620 |
42 |
0.4 |
2 |
| All VG®
ICP-MS, HP® 4500 ICP-MS |
4060-621 |
35 |
1 |
1 |
| ARL® 3400
Series, Accuris® |
4060-010276 |
35 |
0.7 |
2 |
| Finnigan®
ICP-MS |
4060-010280 |
40 |
1 |
1 |
| Micromass® |
4060-010364 |
40 |
1 |
2 |
| Spectro® |
4060-010366 |
27 |
0.75 |
3 |
| HP® 4500,
Other Instruments, Varian® |
4060-010158 |
35 |
1 |
0.2 |
| (call
for other sample flow rates) |
|
|
|